| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SiRcom SMART Alert (SiSA) allows unauthorized access to backend APIs. This allows an unauthenticated attacker to bypass the login screen using browser developer tools, gaining access to restricted parts of the application. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled. |
| A vulnerability in the handling of verify_mode = CERT_REQUIRED in the wolfssl Python package (wolfssl-py) causes client certificate requirements to not be fully enforced.
Because the WOLFSSL_VERIFY_FAIL_IF_NO_PEER_CERT flag was not included, the behavior effectively matched CERT_OPTIONAL: a peer certificate was verified if presented, but connections were incorrectly authenticated when no client certificate was provided.
This results in improper authentication, allowing attackers to bypass mutual TLS (mTLS) client authentication by omitting a client certificate during the TLS handshake.
The issue affects versions up to and including 5.8.2. |
| A vulnerability was found in Excitel Broadband Private my Excitel App 3.13.0 on Android. It has been classified as problematic. Affected is an unknown function of the component One-Time Password Handler. The manipulation leads to improper restriction of excessive authentication attempts. The vendor was contacted early about this disclosure but did not respond in any way. |
| Lack of Rate Limiting in Sign-up workflow in Perforce Gliffy prior to version 4.14.0-7 on Gliffy online allows attacker to enumerate valid user emails and potentially DOS the server |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 do not enforce rate limiting on password reset attempts, allowing adversaries to brute force guess the 6-digit password reset PIN |
| NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure. |
| NVIDIA Isaac Lab contains a vulnerability in SB3 configuration parsing. A successful exploit of this vulnerability might lead to code execution, denial of service, escalation of privileges, information disclosure, or data tampering. |
| A vulnerability, which was classified as critical, has been found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this issue is some unknown functionality of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| Missing Authentication & Authorization in Web-API in Mobatime AMX MTAPI v6 on IIS allows adversaries to unrestricted access via the network. The vulnerability is fixed in Version 1.5. |
| Authelia is an open-source authentication and authorization server providing two-factor authentication and single sign-on (SSO) for applications via a web portal. If users are allowed to sign in via both username and email the regulation system treats these as separate login events. This leads to the regulation limitations being effectively doubled assuming an attacker using brute-force to find a user password. It's important to note that due to the effective operation of regulation where no user-facing sign of their regulation ban being visible either via timing or via API responses, it's effectively impossible to determine if a failure occurs due to a bad username password combination, or a effective ban blocking the attempt which heavily mitigates any form of brute-force. This occurs because the records and counting process for this system uses the method utilized for sign in rather than the effective username attribute. This has a minimal impact on account security, this impact is increased naturally in scenarios when there is no two-factor authentication required and weak passwords are used. This makes it a bit easier to brute-force a password. A patch for this issue has been applied to versions 4.38.19, and 4.39.0. Users are advised to upgrade. Users unable to upgrade should 1. Not heavily modify the default settings in a way that ends up with shorter or less frequent regulation bans. The default settings effectively mitigate any potential for this issue to be exploited. and 2. Disable the ability for users to login via an email address. |
| A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows a high privileged remote attacker to read files from the system’s file structure. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| Unexpected authentication form rendering in HTML Form Adapter using only non-default redirectless mode in PingFederate allows authentication attempts which may enable brute force login attacks. |
| The devices do not implement any authentication for the web interface or the MQTT server. An attacker who has network access to the device immediately gets administrative access to the devices and can perform arbitrary administrative actions and reconfigure the devices or potentially gain access to sensitive data. |
| The OTP Integration Kit for PingFederate fails to enforce HTTP method validation and state validation properly. The server advances the authentication state without verifying the OTP, thereby bypassing multi-factor authentication. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the launched SSH server.
First identified on Nissan Leaf ZE1 manufactured in 2020. |