| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An information disclosure vulnerability exists in Ruijie NBR series routers (known to affect NBR2000G, NBR1300G, and NBR1000 models) via the /WEB_VMS/LEVEL15/ endpoint. By crafting a specific POST request with modified Cookie headers and specially formatted parameters, an unauthenticated attacker can retrieve administrative account credentials in plaintext. This flaw allows direct disclosure of sensitive user data due to improper authentication checks and insecure backend logic. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) versions prior to 1.3.4 contain an authentication bypass in the NVMS-9000 control protocol. By sending a single crafted TCP payload to an exposed NVMS-9000 control port, an unauthenticated remote attacker can invoke privileged administrative query commands without valid credentials. Successful exploitation discloses sensitive information including administrator usernames and passwords in cleartext, network and service configuration, and other device details via commands such as queryBasicCfg, queryUserList, queryEmailCfg, queryPPPoECfg, and queryFTPCfg. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| The Malware Scanner plugin and the Web Application Firewall plugin for WordPress (both by MiniOrange) are vulnerable to privilege escalation due to a missing capability check on the mo_wpns_init() function in all versions up to, and including, 4.7.2 (for Malware Scanner) and 2.1.1 (for Web Application Firewall). This makes it possible for unauthenticated attackers to escalate their privileges to that of an administrator. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| LinkJoin through 882f196 mishandles token ownership in password reset. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| Toshiba printers provides API without authentication for internal access. A local attacker can bypass authentication in applications, providing administrative access. As for the affected products/models/versions, see the reference URL. |
| Improper Restriction of Excessive Authentication Attempts vulnerability in LoginPress LoginPress Pro allows Removing Important Client Functionality.This issue affects LoginPress Pro: from n/a before 3.0.0. |
| Improper Restriction of Excessive Authentication Attempts vulnerability in CodePeople Appointment Hour Booking allows Removing Important Client Functionality.This issue affects Appointment Hour Booking: from n/a through 1.4.56. |
| An issue in the BYD Dilink Headunit System v3.0 to v4.0 allows attackers to bypass authentication via a bruteforce attack. |
| A unauthorized access vulnerability exists in the Xiaomi phone framework. The vulnerability is caused by improper validation and can be exploited by attackers to Access sensitive methods. |
| The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated
communications with ICU, which may allow an attacker to gain unauthorized access |