Search Results (1610 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-44643 1 Draytek 3 Ap903, Ap912c, Ap918r 2026-04-15 8.6 High
Certain Draytek products are affected by Insecure Configuration. This affects AP903 v1.4.18 and AP912C v1.4.9 and AP918R v1.4.9. The setting of the password property in the ripd.conf configuration file sets a hardcoded weak password, posing a security risk. An attacker with network access could exploit this to gain unauthorized control over the routing daemon, potentially altering network routes or intercepting traffic.
CVE-2025-4412 1 Sparklabs 1 Viscosity 2026-04-15 N/A
On macOS systems, by utilizing a Launch Agent and loading the viscosity_openvpn process from the application bundle, it is possible to load a dynamic library with Viscosity's TCC (Transparency, Consent, and Control) identity. The acquired resource access is limited without entitlements such as access to the camera or microphone. Only user-granted permissions for file resources apply. Access to other resources beyond granted-permissions requires user interaction with a system prompt asking for permission. This issue was fixed in version 1.11.5 of Viscosity.
CVE-2025-13131 1 Sonarr 1 Sonarr 2026-04-15 7.8 High
A vulnerability was found in Sonarr 4.0.15.2940. The impacted element is an unknown function of the file C:\ProgramData\Sonarr\bin\Sonarr.Console.exe of the component Service. Performing manipulation results in incorrect default permissions. The attack is only possible with local access. The vendor confirms this vulnerability but classifies it as a "low severity issue due to the default service user being used as it would either require someone to intentionally change the service to a highly privileged account or an attacker would need an admin level account". It is planned to fix this issue in the next major release v5.
CVE-2025-13130 1 Radarr 1 Radarr 2026-04-15 7.8 High
A vulnerability has been found in Radarr 5.28.0.10274. The affected element is an unknown function of the file C:\ProgramData\Radarr\bin\Radarr.Console.exe of the component Service. Such manipulation leads to incorrect default permissions. The attack can only be performed from a local environment. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11575 2 Microsoft, Mongodb 2 Windows, Mongodb 2026-04-15 7.8 High
Incorrect Default Permissions vulnerability in MongoDB Atlas SQL ODBC driver on Windows allows Privilege Escalation.This issue affects MongoDB Atlas SQL ODBC driver: from 1.0.0 through 2.0.0.
CVE-2025-11567 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2024-5321 1 Redhat 1 Openshift 2026-04-15 6.1 Medium
A security issue was discovered in Kubernetes clusters with Windows nodes where BUILTIN\Users may be able to read container logs and NT AUTHORITY\Authenticated Users may be able to modify container logs.
CVE-2024-52946 1 Lemonldap-ng 1 Lemonldap-ng 2026-04-15 8.8 High
An issue was discovered in LemonLDAP::NG before 2.20.1. An Improper Check during session refresh allows an authenticated user to raise their authentication level if the admin configured an "Adaptative authentication rule" with an increment instead of an absolute value.
CVE-2024-52867 1 Gnu 1 Guix 2026-04-15 8.1 High
guix-daemon in GNU Guix before 5ab3c4c allows privilege escalation because build outputs are accessible by local users before file metadata concerns (e.g., for setuid and setgid programs) are properly addressed. The vulnerability can be remediated within the product via certain pull, reconfigure, and restart actions. Both 5ab3c4c and 5582241 are needed to resolve the vulnerability.
CVE-2024-52783 2026-04-15 5.1 Medium
Insecure permissions in the XNetSocketClient component of XINJE XDPPro.exe v3.2.2 to v3.7.17c allows attackers to execute arbitrary code via modification of the configuration file.
CVE-2024-51765 1 Hpe 1 Cray System Management Software 2026-04-15 5.5 Medium
A security vulnerability has been identified in HPE Cray Data Virtualization Service (DVS). Depending on configuration, this vulnerability may lead to local/cluster unauthorized access.
CVE-2024-51764 1 Hpe 1 Sgi Cxfs 2026-04-15 5.5 Medium
A security vulnerability has been identified in HPE Data Management Framework (DMF) Suite (CXFS). Depending on configuration, this vulnerability may lead to local/cluster unauthorized access.
CVE-2024-51440 2026-04-15 7.8 High
An issue in Nothing Tech Nothing OS v.2.6 allows a local attacker to escalate privileges via the NtBpfService component.
CVE-2024-51162 1 Audimex 1 Audimexee 2026-04-15 8.8 High
An issue in Audimex EE versions 15.1.20 and earlier allowing a remote attacker to escalate privileges. Analyzing the offline client code, it was identified that it is possible for any user (with any privilege) of Audimex to dump the whole Audimex database. This gives visibility upon password hashes of any user, ongoing audit data and more.
CVE-2024-51051 1 Avscms 1 Avscms 2026-04-15 9.8 Critical
AVSCMS v8.2.0 was discovered to contain weak default credentials for the Administrator account.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2020-37129 1 Microvirt 2 Memu, Memu Play 2026-04-15 9.8 Critical
Memu Play 7.1.3 contains an insecure folder permissions vulnerability that allows low-privileged users to modify the MemuService.exe executable. Attackers can replace the service executable with a malicious file during system restart to gain SYSTEM-level privileges by exploiting unrestricted file modification permissions.
CVE-2020-37160 1 Microsoft 1 Windows 2026-04-15 6.2 Medium
SprintWork 2.3.1 contains multiple local privilege escalation vulnerabilities through insecure file, service, and folder permissions on Windows systems. Local unprivileged users can exploit missing executable files and weak service configurations to create a new administrative user and gain complete system access.
CVE-2024-49202 1 Keyfactor 1 Command 2026-04-15 7.6 High
Keyfactor Command before 12.5.0 has Incorrect Access Control: access tokens are over permissioned, aka 64099. The fixed versions are 11.5.1.1, 11.5.2.1, 11.5.3.1, 11.5.4.5, 11.5.6.1, 11.6.0, 12.2.0.1, 12.3.0.1, 12.4.0.1, 12.5.0, and 24.4.0.
CVE-2024-48823 1 Automatic Systems 1 Maintenance Slimlane 2026-04-15 9.8 Critical
Local file inclusion in Automatic Systems Maintenance SlimLane 29565_d74ecce0c1081d50546db573a499941b10799fb7 allows a remote attacker to escalate privileges via the PassageAutoServer.php page.