| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple untrusted search path vulnerabilities in installer in Synology Photo Station Uploader before 1.4.2-084 on Windows allows local attackers to execute arbitrary code and conduct DLL hijacking attack via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory. |
| An insecure suid wrapper binary in the HashiCorp Vagrant VMware Fusion plugin (aka vagrant-vmware-fusion) 4.0.24 and earlier allows a non-root user to obtain a root shell. |
| 360 Total Security 9.0.0.1202 before 2017-07-07 allows Privilege Escalation via a Trojan horse Shcore.dll file in any directory in the PATH, as demonstrated by the C:\Python27 directory. |
| mcmnm in BMC Patrol allows local users to gain privileges via a crafted libmcmclnx.so file in the current working directory, because it is setuid root and the RPATH variable begins with the .: substring. |
| An Uncontrolled Search Path or Element issue was discovered in i-SENS SmartLog Diabetes Management Software, Version 2.4.0 and prior versions. An uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could execute arbitrary code on the system. This vulnerability does not affect the connected blood glucose monitor and would not impact delivery of therapy to the patient. |
| An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file. |
| In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. |
| A vulnerability in the Cisco FindIT Network Discovery Utility could allow an authenticated, local attacker to perform a DLL preloading attack, potentially causing a partial impact to the device availability, confidentiality, and integrity, aka Insecure Library Loading. The vulnerability is due to the application loading a malicious copy of a specific, nondefined DLL file instead of the DLL file it was expecting. An attacker could exploit this vulnerability by placing an affected DLL within the search path of the host system. An exploit could allow the attacker to load a malicious DLL file into the system, thus partially compromising confidentiality, integrity, and availability on the device. Cisco Bug IDs: CSCvf37955. |
| An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the application. |
| An untrusted search path (aka DLL Preload) vulnerability in the Cisco Network Academy Packet Tracer software could allow an authenticated, local attacker to execute arbitrary code via DLL hijacking if a local user with administrative privileges executes the installer in the current working directory where a crafted DLL has been placed by an attacker. The vulnerability is due to incomplete input validation of path and file names of a DLL file before it is loaded. An attacker could exploit this vulnerability by creating a malicious DLL file and installing it in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to the SYSTEM account. An attacker would need valid user credentials to exploit this vulnerability. |
| A vulnerability in the routine that loads DLL files in Cisco Meeting App for Windows could allow an authenticated, local attacker to run an executable file with privileges equivalent to those of Cisco Meeting App. The vulnerability is due to incomplete input validation of the path name for DLL files before they are loaded. An attacker could exploit this vulnerability by installing a crafted DLL file in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to those of Cisco Meeting App. The attacker would need valid user credentials to exploit this vulnerability. Cisco Bug IDs: CSCvd77907. |
| There exists a path traversal vulnerability in the Android Google Search app. This is caused by the incorrect usage of uri.getLastPathSegment. A symbolic encoded string can bypass the path logic to get access to unintended directories. An attacker can manipulate paths that could lead to code execution on the device. We recommend upgrading beyond version 13.41 |
| Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. |
| DWG TrueViewTM 2023 version has a DLL Search Order Hijacking vulnerability. Successful exploitation by a malicious attacker could result in remote code execution on the target system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. |
| Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges |
| The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22. |
| AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; |
| If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions. |