| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
Franklin Fueling System EVO 550 and EVO 5000 are vulnerable to a Path Traversal vulnerability that could allow an attacker to access sensitive files on the system.
|
| A vulnerability exists in the message queueing mechanism that if
exploited can lead to the exposure of resources or functionality to
unintended actors, possibly providing attackers with sensitive information or even execute arbitrary code. |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. |
| In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed. |
| Attackers with local access to the medical office computer can
escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by
overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is
writable for all users. In addition, the Elefant installer registers two
Firebird database services which are running as “NT AUTHORITY\SYSTEM”.
Path: C:\Elefant1\Firebird_2\bin\fbserver.exe
Path: C:\Elefant1\Firebird_2\bin\fbguard.exe
Both service binaries are user writable. This means that a local
attacker can rename one of the service binaries, replace the service
executable with a new executable, and then restart the system. Once the
system has rebooted, the new service binary is executed as "NT
AUTHORITY\SYSTEM". |
| A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands. |
| The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
|
| Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings. |
| An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| The password is empty in the initial configuration of ACERA 9010-08 firmware v02.04 and earlier, and ACERA 9010-24 firmware v02.04 and earlier. An unauthenticated attacker may log in to the product with no password, and obtain and/or alter information such as network configuration and user information. The products are affected only when running in non MS mode with the initial configuration. |
| In International Color Consortium DemoIccMAX before 85ce74e, a logic flaw in CIccTagXmlProfileSequenceId::ParseXml in IccXML/IccLibXML/IccTagXml.cpp results in unconditionally returning false. |
| An attacker could decrypt sensitive data, impersonate legitimate users
or devices, and potentially gain access to network resources for lateral
attacks. |
| Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions. |
| Charmed MySQL K8s operator is a Charmed Operator for running MySQL on Kubernetes. Before revision 221, the method for calling a SQL DDL or python based mysql-shell scripts can leak database users credentials. The method mysql-operator calls mysql-shell application rely on writing to a temporary script file containing the full URI, with user and password. The file can be read by a unprivileged user during the operator runtime, due it being created with read permissions (0x644). On other cases, when calling mysql cli, for one specific case when creating the operator users, the DDL contains said users credentials, which can be leak through the same mechanism of a temporary file. All versions prior to revision 221 for kubernetes and revision 338 for machine operators. |
| The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later.
Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary. |
| On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc). |
| Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565. |
| BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. |