| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |
| The Java keystore in all versions and editions of Rapid7 Nexpose prior to 6.4.50 is encrypted with a static password of 'r@p1d7k3y5t0r3' which is not modifiable by the user. The keystore provides storage for saved scan credentials in an otherwise secure location on disk. |
| The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account. |
| The WePresent WiPG-1500 device with firmware 1.0.3.7 has a manufacturer account that has a hardcoded username / password. Once the device is set to DEBUG mode, an attacker can connect to the device using the telnet protocol and log into the device with the 'abarco' hardcoded manufacturer account. This account is not documented, nor is the DEBUG feature or the use of telnetd on port tcp/5885. |
| An issue was discovered in Veritas NetBackup Before 8.0 and NetBackup Appliance Before 3.0. NetBackup Cloud Storage Service uses a hardcoded username and password. |
| A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges. |
| Intellinet NFC-30ir IP Camera has a vendor backdoor that can allow a remote attacker access to a vendor-supplied CGI script in the web directory. |
| DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8. |
| Foscam networked devices use the same hardcoded SSL private key across different customers' installations, which allows remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET. |
| A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface. |
| The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) and DPC3941T (firmware version DPC3941_2.5s3_PROD_sey) devices allows remote attackers to access the web UI by establishing a session to the wan0 WAN IPv6 address and then entering unspecified hardcoded credentials. This wan0 interface cannot be accessed from the public Internet. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |