Export limit exceeded: 16594 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (16594 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42601 2026-04-15 N/A
This vulnerability exists in Meon KYC solutions due to insufficient server-side validation of the Captcha in certain API endpoints. A remote attacker could exploit this vulnerability by intercepting the request and removing the Captcha parameter leading to bypassing the Captcha verification mechanism.
CVE-2025-4210 2026-04-15 7.3 High
A vulnerability classified as critical was found in Casdoor up to 1.811.0. This vulnerability affects the function HandleScim of the file controllers/scim.go of the component SCIM User Creation Endpoint. The manipulation leads to authorization bypass. The attack can be initiated remotely. Upgrading to version 1.812.0 is able to address this issue. The name of the patch is 3d12ac8dc2282369296c3386815c00a06c6a92fe. It is recommended to upgrade the affected component.
CVE-2025-41720 1 Sauter 2 Ey-modulo 5 Devices, Modulo 6 Devices 2026-04-15 4.3 Medium
A low privileged remote attacker can upload arbitrary data masked as a png file to the affected device using the webserver API because only the file extension is verified.
CVE-2025-41645 2026-04-15 8.6 High
An unauthenticated remote attacker could use a demo account of the portal to hijack devices that were created in that account by mistake.
CVE-2025-41402 1 Gallagher 1 Command Centre 2026-04-15 5.5 Medium
Client-Side Enforcement of Server-Side Security (CWE-602) in the Command Centre Server allows a privileged operator to enter invalid competency data, bypassing expiry checks. This issue affects Command Centre Server:  9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), all versions of 9.00 and prior.
CVE-2025-41351 1 Funambol 1 Funambol 2026-04-15 N/A
Vulnerability that allows a Padding Oracle Attack to be performed on the Funambol v30.0.0.20 cloud server. The thumbnail display URL allows an attacker to decrypt and encrypt the parameters used by the application to generate ‘self-signed’ access URLs.
CVE-2025-41224 2026-04-15 8.8 High
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.10.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RSL910NC (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products do not properly enforce interface access restrictions when changing from management to non-management interface configurations until a system reboot occurs, despite configuration being saved. This could allow an attacker with network access and credentials to gain access to device through non-management and maintain SSH access to the device until reboot.
CVE-2025-41116 1 Grafana 1 Grafana 2026-04-15 N/A
When using the Grafana Databricks Datasource Plugin, if Oauth passthrough is enabled on the datasource, and multiple users are using the same datasource at the same time on a single Grafana instance, it  could result in  the wrong user identifier being used, and information for which the viewer is not authorized being returned.  This issue affects Grafana Databricks Datasource Plugin: from 1.6.0 before 1.12.0
CVE-2020-37192 2 Password-solutions, Top Password Software 2 Office Password Recovery, Msn Password Recovery 2026-04-15 6.2 Medium
MSN Password Recovery 1.30 contains an XML external entity injection vulnerability that allows attackers to read local system files through crafted XML input. Attackers can exploit the 'Favorites' tab by injecting a malicious XML file that references external entities to retrieve sensitive system configuration information.
CVE-2025-41069 1 T-innova 1 Deporsite 2026-04-15 N/A
Insecure Direct Object Reference (IDOR) vulnerability in DeporSite of T-INNOVA. This vulnerability allows an attacker to access or modify unauthorized resources by manipulating requests using the 'idUsuario' parameter in ‘/ajax/TInnova_v2/Formulario_Consentimiento/llamadaAjax/obtenerDatosConsentimientos’, which could lead to the exposure or alteration os confidential data.
CVE-2023-38693 2026-04-15 9.8 Critical
Lucee Server (or simply Lucee) is a dynamic, Java based, tag and scripting language used for rapid web application development. The Lucee REST endpoint is vulnerable to RCE via an XML XXE attack. This vulnerability is fixed in Lucee 5.4.3.2, 5.3.12.1, 5.3.7.59, 5.3.8.236, and 5.3.9.173.
CVE-2025-1107 2026-04-15 9.9 Critical
Unverified password change vulnerability in Janto, versions prior to r12. This could allow an unauthenticated attacker to change another user's password without knowing their current password. To exploit the vulnerability, the attacker must create a specific POST request and send it to the endpoint ‘/public/cgi/Gateway.php’.
CVE-2025-10947 2026-04-15 5.3 Medium
A flaw has been found in Sistemas Pleno Gestão de Locação up to 2025.7.x. The impacted element is an unknown function of the file /api/areacliente/pessoa/validarCpf of the component CPF Handler. Executing a manipulation of the argument pes_cpf can lead to authorization bypass. The attack can be executed remotely. The exploit has been published and may be used. Upgrading to version 2025.8.0 is sufficient to resolve this issue. It is advisable to upgrade the affected component.
CVE-2025-10910 2026-04-15 N/A
A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account. The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself. The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models. The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately. Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations.
CVE-2025-10905 2 Avast, Microsoft 2 Free Antivirus, Windows 2026-04-15 4.4 Medium
Collision in MiniFilter driver in Avast Software Avast Free Antivirus  before 25.9  on Windows allows a local attacker with administrative privileges to disable real-time protection and self-defense mechanisms.
CVE-2025-10854 2026-04-15 8.1 High
The txtai framework allows the loading of compressed tar files as embedding indices. While the validate function is intended to prevent path traversal vulnerabilities by ensuring safe filenames, it does not account for symbolic links within the tar file. An attacker is able to write a file anywhere in the filesystem when txtai is used to load untrusted embedding indices
CVE-2025-10719 1 Wisdomgarden 1 Tronclass 2026-04-15 4.3 Medium
Tronclass developed by WisdomGarden has an Insecure Direct object Reference vulnerability, allowing remote attackers with regular privilege to modify a specific parameter to access other users' files.
CVE-2025-10640 1 Efficientlab 1 Workexaminer Professional 2026-04-15 9.8 Critical
An unauthenticated attacker with access to TCP port 12306 of the WorkExaminer server can exploit missing server-side authentication checks to bypass the login prompt in the WorkExaminer Professional console to gain administrative access to the WorkExaminer server and therefore all sensitive monitoring data. This includes monitored screenshots and keystrokes of all users. The WorkExaminer Professional console is used for administrative access to the server. Before access to the console is granted administrators must login. Internally, a custom protocol is used to call a respective stored procedure on the MSSQL database. The return value of the call is not validated on the server-side. Instead it is only validated client-side which allows to bypass authentication.
CVE-2025-10622 1 Redhat 4 Satellite, Satellite Capsule, Satellite Maintenance and 1 more 2026-04-15 8 High
A flaw was found in Red Hat Satellite (Foreman component). This vulnerability allows an authenticated user with edit_settings permissions to achieve arbitrary command execution on the underlying operating system via insufficient server-side validation of command whitelisting.
CVE-2025-10355 1 Molgenis 1 Emx2 2026-04-15 N/A
Open redirection vulnerability in MOLGENIS EMX2 v11.14.0. This vulnerability allows an attacker to create a malicious URL using a manipulated redirection parameter, potentially leading users to phishing sites or other malicious destinations via “/%2f%2f<MALICIOUS_DOMAIN>”.